For Physicians & Medical Practices
Precision or frequency? Your patients need both.
DEXA is the gold standard — but you can't scan a patient every week. Bioimpedance is fast, radiation-free, and staff-operable — but it isn't a reference standard. Run them together and you get what neither delivers alone: an accurate baseline and the interval data to see what's actually happening between scans.
Add Bioimpedance — $9,995 Talk DEXA With Our Team
The Clinical Gap
A quarterly measurement can't provide a rapid correction.
Body composition is now central to how we manage metabolic disease, GLP-1 therapy, sarcopenia, and bone health. But the way most practices measure it leaves a blind spot.
A DEXA scan delivers a precise, reference-standard picture — and even on a disciplined quarterly schedule, the patient then walks out and you don't see another data point for three to four months. Meanwhile the intervention you prescribed is doing something to their lean mass right now. Weight and BMI can't tell you what. By the time the next scan confirms muscle loss, an entire treatment cycle of it has already happened.
The answer isn't choosing a modality. It's sequencing two.
Complementary, Not Competing
What each modality is actually good at.
DEXA
The gold standard for body composition and bone mineral density. Highest precision, regional and whole-body fat, lean mass, and BMD in one acquisition.
- Reference-standard accuracy for the baseline
- Bone mineral density — T-score and Z-score
- The measurement you document and act on
Constraints: radiologic technologist and medical oversight requirements, radiation & large dedicated space
Bioimpedance
Fast, radiation-free, staff-operable analysis in under a minute — built for repeat measurement at every visit.
- Frequent trend data between scans
- Segmental muscle, visceral fat, extracellular water
- No supervision, no radiation, small footprint
Constraints: an estimation method, not a reference standard — strongest when used for trends under consistent conditions.
The Integrated Protocol
Anchor with DEXA. Monitor with bioimpedance.
A simple, repeatable workflow your staff can run without adding physician time.
Anchor
DEXA at intake establishes the reference-standard baseline — lean mass, fat mass, visceral fat, and BMD.
Monitor
Bioimpedance at every follow-up visit tracks the direction of change between scans, in under a minute.
Re-anchor
Repeat DEXA every 3–4 months to confirm the trend against the reference standard and reset the baseline.
| DEXA | Bioimpedance | |
|---|---|---|
| Role | Reference-standard baseline | Interval trend monitoring |
| Cadence | Every 3–4 months | Every visit |
| Operator | Licensed technologist + oversight | Any trained staff member |
| Radiation | Low-dose ionizing | None |
| Time | ~5–10 minutes | Under a minute |
| Unique output | Bone mineral density (T/Z-score) | Segmental data, ECW, cellular age |
Bioimpedance is an estimation method and is not a substitute for DEXA where reference-standard measurement or bone densitometry is indicated. Operating and licensure requirements vary by state and scope of practice.
Where It Changes Management
Four patient populations where interval data matters.
GLP-1 therapy
Rapid weight loss can include a substantial lean-mass component. Interval measurement lets you see the fat-to-lean ratio trending in the wrong direction while there's still time to adjust protein intake, resistance training, or titration.
Sarcopenia & aging
Track lean mass and segmental muscle over time in older patients, rather than inferring function from weight that hasn't changed.
Metabolic risk
Visceral fat is a more informative signal than BMI. Anchor it with DEXA, then follow the trajectory visit to visit.
Bone health & longevity
DEXA supplies the BMD picture your bone-health protocol requires; bioimpedance keeps the muscle side of the equation visible in between.
What The Bioimpedance Device Delivers
52 measurements at every visit.
8-Electrode BIA
Clinical-grade whole-body analysis.
Segmental Data
Muscle & fat by arms, legs, and trunk.
Visceral Fat
Central adiposity, tracked over time.
Extracellular Water
Hydration and fluid-distribution insight.
Cellular Age & BMI
Patient-facing metrics that drive adherence.
Ultrasonic Height
Automatic, hands-free measurement.
Facial Recognition
Instant patient identification.
Unlimited Patients
By account or phone number — panel-wide.
Printed & Digital Reports
Share with the patient or the care team.
The Practice Case
Better data, better adherence, better retention.
The clinical argument and the practice argument point the same direction.
- Adherence: patients who see objective progress between visits stay in the protocol. Weight alone discourages them; body composition explains what's actually working.
- Visit value: every follow-up carries a measurable data point instead of a subjective check-in.
- No added physician time: staff run the scan in under a minute; you review the trend.
- Capital efficiency: at $9,995, the bioimpedance device extends the value of a DEXA investment you've already made — or delivers in-house body composition while a DEXA program is still being built.
Implementation
Built to drop into an existing workflow.
Clinical FAQ
Questions physicians ask.
If DEXA is the gold standard, why add bioimpedance?
Because precision and frequency are different problems. DEXA answers "where is this patient, accurately?" Bioimpedance answers "which direction are they moving, right now?" Managing an active intervention requires the second question answered far more often than a DEXA schedule allows.
Is bioimpedance accurate enough to act on?
It's an estimation method, not a reference standard — and that's exactly why it's paired with DEXA rather than replacing it. Its strength is repeat measurement under consistent conditions, where the trend line is highly informative even if any single absolute value carries more variance than DEXA.
How do we keep the two data sets consistent?
Anchor with DEXA, then standardize bioimpedance conditions — same time of day, similar hydration status, consistent pre-scan instructions. Interpret bioimpedance as trend data relative to the DEXA baseline rather than as a direct substitute for its absolute values.
Does the bioimpedance device require oversight or a licensed technologist?
No. Unlike DEXA, it involves no ionizing radiation and no radiologic technologist or medical-supervision requirement, so any trained staff member can operate it. Device and scope-of-practice rules vary by state — confirm what applies to your practice.
What if we don't have DEXA yet?
Many practices start with bioimpedance to build the service line and patient demand, then add DEXA. We supply and support both — our team can walk you through what a combined program looks like for your practice.
DEXA+ Clinical Bioimpedance Device
Add the interval half of the protocol
Free shipping · 1-year warranty · approximately $6,000–$7,000 less than comparable market devices.
- 52 measurements including segmental analysis
- Under a minute per patient, staff-operated
- Unlimited patient records, printed or digital reports
Build the complete body composition program.
Add bioimpedance today, or talk with our team about implementing DEXA and bioimpedance together in your practice.
Buy the Bioimpedance Device Schedule a DEXA ConsultationThis page is intended for licensed healthcare professionals and is provided for educational purposes only. It is not medical advice and does not constitute a clinical guideline. Bioimpedance analysis is an estimation method and is not a substitute for DEXA where reference-standard body composition or bone densitometry measurement is clinically indicated. Equipment operating, licensure, and supervision requirements vary by jurisdiction and scope of practice.